STD5000 / STD6000 Transducer

Brand: Thermo Fisher Scientific

Ensure reliable signal conversion in the most demanding industrial environments with Thermo Scientific™ STD5000 and STD6000 Current-to-Pressure (I/P) Transducers.

Setting the standard in the industry for electronic input signal conversion, these transducers ensure accuracy, reliability and ease-of-use to facilitate operations and increase productivity.

Innovative, Field-Proven Design and Superior Technology
Accurate, repeatable performance minimizes maintenance and increases process optimization Field-proven E-Pi technology is unaffected by vibration, shock or mounting position Intrinsically safe or explosion-proof models are available.
Features
  • Accuracies of ± 0.15% to ± 0.25% of span
  • High supply pressure ranges of 35 psiG to 100 psiG available with selected output ranges
  • Operating temperature range of -40 to +66 °C (-40 to +150 °F)
  • Rugged NEMA 4X and IP65 enclosure
  • Field selectable direct and reverse modes

Specifications

Accuracy

  • ± 0.15 % of Span (psig: 3 to 15 & 1 to 17 Output)
  • ± 0.25 % of Span (psig: 3 to 27 & 6 to 30 Output)

Approvals & Certifications

  • ATEX
  • CE
  • CENELEC
  • CSA
  • FM

Deadband, Approximate

  • 0.02 % of Span

Electrical Connectors

  • 1/2” NPT Female Conduit Connection

Enclosure Finish

  • Epoxy Paint

Enclosure, Body Material

  • Cast Aluminum

Environmental Protection

  • Explosion-proof
  • Flameproof
  • Intrinsically Safe
  • IP65
  • NEMA 4X / IP65

Exhaust Capacity - Relieving Units Only

  • 4 scfm

Frequency

  • -3 Db at 5 Hz Per ISA S26.4.3.1 Load Configuration A

Hysteresis

  • 0.1 % of Full Scale

NPT Connection

  • 1/4” NPT Female

Operating Temperature

  • -40° to 66° C (-40° to 150° F)

Output Pressure

  • psig: 1 to 17 (bar: 0.068 to 1.17, kPa: 6.89 to 117.2)
  • psig: 3 to 27 (bar: 0.20 to 1.86, kPa: 20.6 to 186.1)
  • psig: 6 to 30 (bar: 0.41 to 2.06, kPa: 41.3 to 206.8)

Position Effect

  • No Measurable Effect

Relief

  • Relieving

Repeatability

  • 0.05%

Signal Impedance

  • None

Stability

  • ≤ 0.5 % of Full Scale Output/Year

Supply Pressure

  • High Pressure: for Outputs of psig: 3 to 15 (bar: 0.2 to 1.0, kPa: 20 to 100) Supply Range is psig: 35 to 100 (bar: 2.4 to 6.9, kPa: 240 to 690)
  • Standard: Min. of 3 psig And, Max.

Supply Pressure Effect

  • None Detected

Temperature Effect

  • Range -18° to 65.5° C (0° to 150° F): ± 0.02 % of Span
  • Range -40° to 65.5° C (-40° to 150° F): ± 0.04 % of Span

Vent

  • Straight

Vibration Effect

  • < 0.25 % from 1-200 Hz/1 G

show more